International Journal of Dermatology, EarlyView.
https://ift.tt/2uKQglU
Αρχειοθήκη ιστολογίου
-
▼
2023
(256)
-
▼
Φεβρουαρίου
(140)
-
▼
Φεβ 19
(17)
- Implementable Deep Learning for Multi‐sequence Pro...
- An evaluation of mechanical and biophysical skin p...
- Multifunctional Two-Dimensional Bi2Se3 Nanodiscs f...
- An integrated strategy to identify COVID‐19 causal...
- Downregulation of miR‐193a/b‐3p during HPV‐induced...
- Monitoring of SARS‐CoV‐2 concentration and circula...
- Pustular psoriasis in Malaysia: A review of the Ma...
- The ability of magnetic resonance imaging to predi...
- Nuclear membrane irregularity in high‐grade urothe...
- Impact of Exercise and Detraining on Signs of Pube...
- LRRK2 Inhibition by BIIB122 in Healthy Participant...
- Spermidine reduced neuropathic pain in chronic con...
- Xenogeneic collagen matrix versus connective tissu...
- Tixagevimab/Cilgavimab Treatment and Cardiovascula...
- Recombinant measles virus encoding the spike prote...
- Characterization of protein-based risk signature t...
- Acute Posterior Multifocal Placoid Pigment Epithel...
-
▼
Φεβ 19
(17)
- ► Ιανουαρίου (116)
-
▼
Φεβρουαρίου
(140)
-
►
2022
(1695)
- ► Δεκεμβρίου (78)
- ► Σεπτεμβρίου (142)
- ► Φεβρουαρίου (155)
-
►
2021
(5507)
- ► Δεκεμβρίου (139)
- ► Σεπτεμβρίου (333)
- ► Φεβρουαρίου (628)
-
►
2020
(1810)
- ► Δεκεμβρίου (544)
- ► Σεπτεμβρίου (32)
- ► Φεβρουαρίου (28)
-
►
2019
(7684)
- ► Δεκεμβρίου (18)
- ► Σεπτεμβρίου (53)
- ► Φεβρουαρίου (2841)
- ► Ιανουαρίου (2803)
-
►
2018
(31838)
- ► Δεκεμβρίου (2810)
- ► Σεπτεμβρίου (2870)
- ► Φεβρουαρίου (2420)
- ► Ιανουαρίου (2395)
-
►
2017
(31987)
- ► Δεκεμβρίου (2460)
- ► Σεπτεμβρίου (2605)
- ► Φεβρουαρίου (2785)
- ► Ιανουαρίου (2830)
-
►
2016
(5308)
- ► Δεκεμβρίου (2118)
- ► Σεπτεμβρίου (877)
- ► Φεβρουαρίου (41)
- ► Ιανουαρίου (39)
Τρίτη 3 Απριλίου 2018
Recognition of early melanoma: a monocentric dermoscopy follow‐up study comparing de novo melanoma with nevus‐associated melanoma
Δευτέρα 2 Απριλίου 2018
Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery
Abstract
Purpose
The fourth-generation FloTrac/Vigileo™ improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery by comparing the FloTrac/Vigileo™-derived CI (CIFT) with that measured by three-dimensional echocardiography (CI3D).
Methods
Twenty-six patients undergoing elective AAA surgery were included in this study. CIFT and CI3D were determined simultaneously in eight points including before and after aortic clamp. We used CI3D as the reference method.
Results
In the Bland–Altman analysis, CIFT had a wide limit of agreement with CI3D showing a percentage error of 46.7%. Subgroup analysis showed that the percentage error between CO3D and COFT was 56.3% in patients with cardiac index < 2.5 L/min/m2 and 28.4% in patients with cardiac index ≥ 2.5 L/min/m2. SVRI was significantly higher in patients with cardiac index < 2.5 L/min/m2 (1703 ± 330 vs. 2757 ± 798; p < 0.001). The tracking ability of fourth generation of FloTrac/Vigileo™ after aortic clamp was not clinically acceptable (26.9%).
Conclusions
The degree of accuracy of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo™ after aortic clamp was below the acceptable limit.
https://ift.tt/2Gu2twG
Trends in the Implementation of Active Surveillance for Low-Risk Papillary Thyroid Microcarcinomas at Kuma Hospital: Gradual Increase and Heterogeneity in the Acceptance of This New Management Option
Thyroid, Ahead of Print.
https://ift.tt/2Gwd7mO
Quantitative Analysis of the Benefits and Risk of Thyroid Nodule Evaluation in Patients ≥70 Years Old
Thyroid, Ahead of Print.
https://ift.tt/2pZVV2J
Seasonal Changes in Serum TSH Concentrations Observed from Big Data Obtained During Six Consecutive Years from 2010 to 2015 at a Single Hospital in Japan
Thyroid, Ahead of Print.
https://ift.tt/2GwcTMu
Application of wavelet analysis to detect dysfunction in cerebral blood flow autoregulation during experimental hyperhomocysteinaemia
Abstract
The purpose of the present study was to investigate the use of laser Doppler flowmetry (LDF) signals coupled with spectral wavelet analysis to detect endothelial link dysfunction in the autoregulation of cerebral blood flow in the setting of hyperhomocysteinaemia (HHcy). Fifty-one rats were assigned to three groups (intact, control, and HHcy) according to the results of biochemical assays of homocysteine level in blood plasma. LDF signals on the rat brain were recorded by LAKK-02 device to measure the microcirculatory blood flow. The laser operating wavelength and output power density were1064 nm and 0.051 W/mm2, respectively. A Morlet mother wavelet transform was applied to the measured 8-min LDF signals, and periodic oscillations with five frequency intervals were identified (0.01–0.04 Hz, 0.04–0.15 Hz, 0.15–0.4 Hz, 0.4–2 Hz, and 2–5 Hz) corresponding to endothelial, neurogenic, myogenic, respiratory, and cardiac origins, respectively. In initial state, the amplitude of the oscillations decreased by 38% (P < 0.05) in the endothelial range in HHcy rats than in control rats. Cerebral autoregulation was challenged by hemorrhagic hypotension. The lower limit of autoregulation raised in a rat model of chronic HHcy (71.5 ± 0.7 mmHg in HHcy vs. 62.3 ± 0.5 mmHg in control). The data obtained indicate that the laser Doppler method and wavelet analysis may be successfully applied to detect the dysfunction of the endothelial link in cerebral vessel tone and to reveal the pathological shift of lower limit of autoregulation.
https://ift.tt/2uKbujX
“Hanger” in Intubation and Laryngoscopy
Abstract
Achieving an adequate exposure in laryngoscopy is an extremely tedious task for the operating surgeon, especially for the anterior commissure lesions. Various maneuvers have been described to overcome this difficulty, but failed in providing an adequate exposure leading to a poor outcome. To create a device that can deliver uniform pressure over the laryngeal cartilage and succeed in providing an adequate exposure of the glottic lesion. A total of 44 patients were included in the study, divided into two groups containing 22 patients each. The distance at the level of anterior commissure from the superior border of the distal end of the laryngoscope was noted and compared. Group A subjected to digital cricoid pressure showed a mean distance of 9.09 of exposure with variance of 1.22 and Group B subjected to cricoid pressure with the cricoid catapult showed a mean distance of 11.76 with variance of 1.59. The groups were statistically analyzed using Anova Test and the test was found to be very significant (p < 0.0001). The catapult is made of a hanger defining its economics, which has a vital role in difficult intubations especially in anterior placed larynx, short neck and obese patients, also succeeds in providing an adequate exposure of the glottic lesion, (especially the anterior commissure) by delivering uniform pressure over the laryngeal cartilage, leading to a superior operative outcome.
https://ift.tt/2JdE8gr