Αρχειοθήκη ιστολογίου

Αλέξανδρος Γ. Σφακιανάκης
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5
Άγιος Νικόλαος Κρήτη 72100
2841026182
6032607174

Πέμπτη 1 Φεβρουαρίου 2018

Intraoperative monitoring of marginal mandibular nerve during neck dissection

Abstract

Background

The purpose of this study was to assess the efficacy of intraoperative nerve integrity monitoring (NIM) to prevent marginal mandibular nerve injuries during neck dissection.

Methods

This prospective study compared 36 patients undergoing NIM-assisted neck dissection from July 2014 to March 2015 to a cohort of 35 patients subjected to neck dissection over an identical period of time before the technique was introduced. We also assessed possible correlations between marginal mandibular nerve injuries and other factors, such as anthropometric measurements, presence of clinical neck metastases, type of neck dissection, and site of primary tumor.

Results

The incidence of marginal mandibular nerve paralyses was significantly lower among the group of patients undergoing NIM-assisted neck dissection (P = .021). There was no significant difference in the duration of the procedure, and the technique resulted in a limited increase of cost. No other factor seemed to influence the onset of marginal mandibular nerve palsy.

Conclusion

In our opinion, NIM is a valuable aid for preventing marginal mandibular nerve injuries during neck dissection.



http://ift.tt/2DSpo7x

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου