Publication date: Available online 25 July 2018
Source: Journal of Cranio-Maxillofacial Surgery
Author(s): S.E.C.M. van de Vijfeijken, R. Schreurs, L. Dubois, A.G. Becking, A.G. Becking, L. Dubois, L.H.E. Karssemakers, D.M.J. Milstein, S.E.C.M. van de Vijfeijken, P.R.A.M. Depauw, F.W.A. Hoefnagels, W.P. Vandertop, C.J. Kleverlaan, T.J.A.G. Münker, T.J.J. Maal, E. Nout, M. Riool, S.A.J. Zaat
Abstract
Purpose
The aim of this study was to evaluate the accuracy of resection templates in cranioplasties in order to facilitate a one-stage resection and cranial reconstruction. Patients and methods: In three cases, cranial resections were combined with direct reconstructions using the principles of computer-aided design, manufacturing, and surgery. The precision of the resection template was evaluated through a distance map, comparing the planned and final result.
Results
The mean absolute difference between the planned and actual reconstructed contour was less than 1.0 mm. After 3 years, no clinical signs of infection or rejection of the implants were present. The computed tomography scans showed no irregularities, and the aesthetic results remained satisfactory.
Conclusion
One-stage resection and cranial reconstruction using a resection template, control template, and a prefabricated patient-specific implant of poly(ether-ether-ketone) (PEEK) proved to be a viable and safe method.