Αρχειοθήκη ιστολογίου

Αλέξανδρος Γ. Σφακιανάκης
ΩτοΡινοΛαρυγγολόγος
Αναπαύσεως 5
Άγιος Νικόλαος Κρήτη 72100
2841026182
6032607174

Κυριακή 30 Σεπτεμβρίου 2018

Individual Reliability of the Standard Clinical Method vs Patient-Centered Tinnitus Likeness Rating for Assessment of Tinnitus Pitch and Loudness Matching.

Related Articles

Individual Reliability of the Standard Clinical Method vs Patient-Centered Tinnitus Likeness Rating for Assessment of Tinnitus Pitch and Loudness Matching.

JAMA Otolaryngol Head Neck Surg. 2018 Sep 27;:

Authors: Hébert S

Abstract
Importance: Current individualized sound therapies for tinnitus rely on tinnitus pitch assessment, which is commonly derived from the standard clinical 2-alternative forced-choice (2-AFC) approach driven by the examiner. However, this method is limited by lack of individual test-retest reliability and focuses on a single rather than multiple tinnitus frequencies.
Objective: To assess individual test-retest reliability of the 2-AFC, with a single final frequency (and corresponding loudness), and the tinnitus likeness rating (TLR), with the participant exposed to the entire audible frequency spectrum, from which 3 dominant frequencies and corresponding loudness were extracted.
Design, Setting, and Participants: In this case series, participants with tinnitus underwent testing twice with both methods at a 1-month interval by experienced clinicians from January 6 through March 17, 2017. Each clinician tested each patient only once at visit 1 or 2 in a university audiology training setting with standardized equipment and was blind to previous assessment. Participants with bilateral or unilateral chronic tinnitus for longer than 6 months, in good health, without total deafness in either ear, and without cerumen in the ear canal were recruited through advertisements (community and clinics) and word of mouth (volunteer sample). The audiologists were likewise participants in the planned comparison between TLR and 2-AFC in the test-retest measures.
Main Outcomes and Measures: Test-retest concordance with 95% CIs for each method, calculated as the proportion of participants with the same final frequency between the 2 visits (2-AFC) or with at least 1 concordant dominant frequency (TLR) as well as loudness differences of no greater than 10 dB.
Results: The study sample included 31 participants (55% men; mean [SD] age, 50.7 [13.7] years). For TLR, 26 of 31 participants had at least 1 concordant dominant frequency between the 2 visits (proportion, 0.84; 95% CI, 0.66-0.95), whereas for 2-AFC, 7 of 31 participants had a concordant final tinnitus pitch in either ear (proportion, 0.23; 95% CI, 0.10-0.41). Loudness reliability followed the same pattern, with more concordant loudness levels in the TLR (proportion, 0.73; 95% CI, 0.52-0.88) than in the 2-AFC (proportion, 0.40; 95% CI, 0.05-0.85). Mean time taken to complete the tests was less than 15 minutes, and general appreciation by participants with tinnitus and audiologists were overall similar for both.
Conclusions and Relevance: Superior test-retest concordance can be demonstrated at the individual level using the several dominant frequencies extracted from the patient-centered TLR.

PMID: 30267085 [PubMed - as supplied by publisher]



https://ift.tt/2NdqYAS

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου