A Review of In-Office Dynamic Image Navigation for Extraction of Complex Mandibular Third Molars

elsevier-non-solus.png

Publication date: August 2017
Source:Journal of Oral and Maxillofacial Surgery, Volume 75, Issue 8
Author(s): Robert W. Emery, Oxana Korj, Ravi Agarwal
PurposeWe performed a retrospective review of in-office removal of complex mandibular third molars with a dynamic image navigation system (DINS).Materials and MethodsA retrospective review was conducted of cases completed from 2010 to 2014 by a single oral and maxillofacial surgeon. The average age of the patients was 47 years (range, 27 to 72 years). Extraction complexity was classified with Juodzbalys and Daugela's classification system. The included study cases had complexity scores of 9 or greater. Each patient received custom intraoral splints to secure the tracking array and underwent cone beam computed tomography image acquisition. All surgical procedures were performed with a precalibrated tracking straight handpiece under dynamic navigation.ResultsAll 25 cases were treated successfully with the use of the DINS. Twelve of these cases were associated with pathologic lesions. Three patients were noted to have inferior alveolar nerve paresthesia. One patient sustained a pathologic fracture at week 2. Postoperative infections were noted in 7 cases, 2 of which had a pre-existing infection. One patient reported temporary limitation of mouth opening. A coronectomy was performed in 1 case.ConclusionsWe present results using a new technology, the DINS, for removal of complex mandibular third molars. Potential advantages are 1) improved visualization and localization of anatomic structures such as the inferior alveolar nerve, lingual cortical plate, and adjacent roots; 2) improved control during osteotomy; 3) decreased surgical access requirements and reduction in overall bone removal; 4) ability to perform complex procedures successfully in an in-office setting; 5) decreased surgical time resulting from improved visualization; and 6) potential use as a teaching tool. Possible limitations of the use of an in-office DINS include increased cost, increased time attributed to presurgical planning, initial learning curve, and optical array interference by the surgeon or assistants during surgery.



http://ift.tt/2eMEhg5

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου