Publication date: Available online 4 February 2019
Source: Journal of Cranio-Maxillofacial Surgery
Author(s): Philipp Poxleitner, Pit Jacob Voss, David Steybe, Stefan Schlager, Steffen Schwarz, Marc Anton Fuessinger, Rainer Schmelzeisen, Marc Metzger
Abstract
Introduction
Fractures of the mandibular condyle are reported to account for 9 % to 45 % of all mandibular fractures. There has been a long lasting controversy on the superiority of different treatment options with endoscopic-assisted transoral approaches gaining increasing attention in recent years. In this article, we report the application of a newly developed osteosynthesis plate for an auto reposition, reconstruction and rigid fixation of condylar process fractures.
Material and Methods
We present 6 cases of uni- or bilateral fractures of the condylar process treated with a transoral open reduction and rigid fixation using an auto reposition plate. Via a transoral endoscopic assisted approach the proximal condyle fragment is captured using an anatomical defined clinch of the cranial part of the plate. The reposition of the condyle is facilitated with the distal bridge of the plate ranging around the posterior part of the ascending ramus.
Results
The results show a sufficient reposition, rigid fixation and no facial nerve palsy or postoperative long-term occlusal disturbances. The mean operating time was 86 minutes.
Conclusion
Transoral endoscopic-assisted surgery with application of an auto reposition, reconstruction and fixation plate offers a quick and convenient way for open reconstruction and rigid fixation of condylar process fractures.